• Home
  • Products

CO₂ Booster Systems

CO2 Transcritical Booster Refrigeration Systems

The Advansor transcritical booster system utilizes only one refrigerant the abundantly available, completely sustainable and economical CO2. CO2 is neither flammable nor toxic, making it ideal in terms of installation and system operation. Advansor is the most reliable and energy-efficient CO2 refrigeration system on the market.

The Advansor transcritical booster system utilizes only one refrigerant the abundantly available, completely sustainable and economical CO2. CO2 is neither flammable nor toxic, making it ideal in terms of installation and system operation. Advansor is the most reliable and energy-efficient CO2 refrigeration system on the market.

Less

  • Industrial-Refrigeration-CO2-rack-1095.jpg
  • industrial CO2 system diagram v2.png
  • Advansor CO2 Industrial System Enthalpy Diagram Image.jpg
  • industrial-refrigeration-CO2-cold-storage-freezer3.JPG
  • industrial -refrigeration-cold-storage-rack3.JPG
  • industrial-refrigeration-CO2-cold-storage-condensers-2.jpg
  • industrial-refrigeration-CO2-cold-storage-evaps.JPG
  • industrial-refrigeration-CO2-cold-storage-rack.JPG
  • industrial-refrigeration-cold-storage-condensers4.JPG
  • industrial-refrigeration-CO2-cold-storage-condensers7.JPG
  • industrial-refigeration-CO2-cold-storage-controllers.JPG
  • Industrial-Refrigeration-CO2-Cold-Storage-8780.JPG
  • Industrial-Refrigeration-CO2-Cold-Storage-8788.JPG

Installation Manuals

  • Installation-Startup-Guide-Secondary-Refrig-Manual.pdf
  • Secondary-Glycol-Pump-Station-Manual-08-14-2018.pdf
  • Advansor-Booster-Installation-Startup-Operating Manual 06-06...

White Papers

  • Industrial-Regulations-White-Paper.pdf
  • Angelic-Bakery-Industrial-White-Paper.pdf
  • Vermont-Food-Bank-Industrial-White-Paper.pdf
  • Best-Foods-Industrial-White-Paper.pdf
  • House-of-Spice-Industrial-White-Paper.pdf
  • Campbell-Soup-Industrial-White-Paper.pdf

Executive Summaries

  • Industrial Regulations Executive Summary.pdf
  • Redwood Farms Industrial Executive Summary.pdf
  • Angelic Bakery Industrial Executive Summary.pdf
  • Best Foods Industrial Executive Summary.pdf
  • House of Spices Industrial Executive Summary.pdf
  • Vermont Food Bank Industrial Executive Summary.pdf

Sales Literature

  • CO2-Booster-Industrial-Sales-Sheet.pdf
  • Product-Overview-Brochure.pdf

CO2 Transcritical Booster Refrigeration Systems

The Advansor transcritical booster system utilizes only one refrigerant the abundantly available, completely sustainable and economical CO2. CO2 is neither flammable nor toxic, making it ideal in terms of installation and system operation. Advansor is the most reliable and energy-efficient CO2 refrigeration system on the market.

The Advansor transcritical booster system utilizes only one refrigerant the abundantly available, completely sustainable and economical CO2. CO2 is neither flammable nor toxic, making it ideal in terms of installation and system operation. Advansor is the most reliable and energy-efficient CO2 refrigeration system on the market.

Less

Industrial-Refrigeration-CO2-rack-1095.jpg

Download OPEN FULL SCREEN
ADD TO DOWNLOAD LIST

 

Features & Benefits

Features

  • Variable speed drives on lead medium-temperature compressor.
  • Air-cooled and adiabatic gas coolers with variable speed fans as an option.
  • Electronic-controlled high pressure and flash gas bypass valves ensure optimal performance in all ambient conditions.
  • Simple electronic oil management system ensures adequate lubrication for longer compressor life.
  • Reliable, proven reciprocating compressors.
  • Electronic expansion valves provide efficient evaporator operation.

 

Benefits

  • Easier to operate than NH3 systems.
  • More cost-efficient TCO (total cost of ownership) than NH3 in terms of equipment, installation, and service.
  • Quick and simple commissioning.
  • CO2 in cold storage areas and processing areas is safer for product and people than NH3.
  • Systems are lighter weight and command a smaller footprint.
  • 100% HFC free.
  • High quality heat reclaim opportunities for under-floor heating and process heating loads.
  • More efficient than HFC refrigerant systems in certain climates.

 

Options

  • Pre-engineered outdoor enclosure on common frame with or without optional factory-piped gas cooler.
  • De-superheater on low-temperature compressor discharge for increased energy efficiency.
  • Variable frequency drives on low-temperature compressors for increased energy efficiency.

Enter CO2 and Advansor by Hillphoenix

All Advansor booster systems are carefully manufactured to achieve optimal, safe, and service-friendly operation. State-of-the-art oil control, flash gas control, and pressure regulation systems make Advansor the most reliable and energy-efficient CO2 refrigeration system on the market.

 

 

Business owners preparing to invest in a new refrigeration system must weigh all factors that impact their Total Cost of Ownership. Environmental impact and compliance — or lack of compliance — must loom large in those considerations. Supplier credibility is just as important — and Hillphoenix has over a decade of experience and over 1500 transcritical CO2 systems installed worldwide. Hillphoenix closes the deal with a commitment to provide guidance and training in the newest innovations and installation and maintenance best practices through the Hillphoenix Learning Center.

 

 

Here’s how it works.

The cooling cycle begins with liquid CO2 in the flash tank (receiver) (1) A network of pipes distributes the liquid to evaporators specially designed for optimum operation in CO2 transcritical systems. Electronic expansion valves (EEVs) are in place to control the flow of CO2 into those evaporators (2) Suction gas from the lowtemperature evaporators returns to the rack and is compressed by the subcritical compressors to the pressure of the medium-temperature evaporators (3) Suction gas from the medium-temperature evaporators returns to the rack and is combined with discharge gas from the low-temperature compressors and flash gas exiting the flash tank via the flash gas bypass valve (4) This mixture enters the transcritical compressors and is compressed to high pressure (5) From there it is sent to the gas cooler where it is cooled to near ambient temperature — in cooler weather, the CO2 in the gas cooler condenses similar to conventional systems (6) From the gas cooler, the CO2 enters the high-pressure control valve where it is expanded back to subcritical pressures (7) The CO2 then enters the flash tank where it is separated into liquid and gas — and the cycle begins again.

 

Related Products

Ice Rink Refrigeration Systems

Hillphoenix offers synthetic and natural refrigerant solutions for ice rinks of all shapes and sizes. For facilities that are "future-focused"…

Parallel Rack Systems

Parallel Racks by Hillphoenix® are custom-designed platforms that offer the ultimate in flexibility, performance, and efficiency to the industrial refrigeration…

PowerWall Power System

PowerWall is a cost-effective, flexible power distribution and control system for a wide variety of industrial applications. Totally integrated units…

Mechanical Center

Hillphoenix® makes sure you get nothing short of the best-designed, best-built, industrial refrigeration mechanical centers possible. Our proven “work cell”…

Downloads

PRODUCT COMPARISON

Quick view

Go to Top